Every case below is a real call to our 24/7 truck dispatch. We remove names, phone numbers, companies and prices, and keep what helps the next driver: the symptoms, what was checked on the call and what usually fixes it. Broken down right now? Call (855) 450-1212 or request service.
Photo from a similar MTS job: Dash volvo check engine night
Truck: 2020 Volvo VNL 760 D13 automatic
Driver asked: Why is my 2020 Volvo VNL 760 cranking but failing to start after draining the fuel filter?
On the call: Driver drained the fuel filter and the fuel system was not primed, causing a crank no-start condition; cause not confirmed on the call.
When a Volvo VNL with a D13 engine cranks normally but refuses to fire after fuel filter maintenance, air in the low-pressure fuel system is almost always the prime suspect. Draining or changing fuel filters introduces air pockets into the fuel housing and… Full case →
2026-11-23 · PA · PA Turnpike westbound at Sideling Hill Service Plaza
Photo from a similar MTS job: Dash prime fuel system
Truck: 2020 Volvo VNL 760 D13
Driver asked: Why is my 2020 Volvo VNL 760 D13 engine cranking over strong but refusing to fire after draining the fuel filter?
On the call: Engine cranks normally but will not start. The driver drained the fuel filter and the fuel system was not primed. Cause not confirmed on the call.
When a Volvo D13 engine cranks over strong but refuses to fire, the issue is almost always related to fuel delivery or air trapped in the low-pressure fuel system. If a fuel filter is drained or serviced without properly priming the system, air gets trapped… Full case →
Photo from a similar MTS job: Dash volvo check engine night
Truck: 2020 Volvo VNL 760 D13
Driver asked: Why is my 2020 Volvo VNL 760 D13 cranking continuously but refusing to start?
On the call: The engine turned over continuously with strong 12.7V battery power and adequate fuel in tanks, but would not fire. The driver opened the fuel filter drain valve to check for debris. Cause not…
When a Volvo VNL with a D13 engine cranks over strongly with good battery voltage but fails to start, the issue is usually related to fuel supply or electronic engine controls rather than a starter failure. Opening the fuel filter drain valve without properly… Full case →
Updated 2026-11-23. Full write-ups are kept on our repair-answers library.
From the road: latest real jobs
Real breakdown calls to our 24/7 dispatch, written up without names or prices. Updated every hour.
Transmission and truck brand names (Eaton Fuller, Eaton Endurant, Detroit DT12, Volvo I-Shift, Mack mDrive, Allison, Meritor, Dana Spicer) are used only to describe the equipment we work on. MTS Driveline & Transmission is a service of MTS Mobile Truck Repair Service LLC and is not affiliated with any manufacturer.